• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Place of Origin: Guangdong, China (Mainland)
  • Brand Name: Dienmern
  • Model Number: DM-103
  • Detecting Gas: PM2.5/PM1.0/PM10/TVOC/HCHO/AQI
  • Sensor: Laser
  • Material: ABS with TFT LCD screen
  • Product size: 100*95*47MM
  • Weight: 400g
  • Battery Capacity: 2200mA
  • Color: white black
  • PM2.5 range: 0-1000
  • HCHO range: 0.001-1.999Mg/M3
  • TVOC range: 0.001-9.999Mg/M3

Packaging & Delivery

Packaging Details Color Box
what are included :Main Unit+ manual+charging cable
Packing :20pcs/ctn, Carton size : 77*37*33.5Cm
G.W:19KG
Delivery Time sample time 3-7days / lead time 20-25days
Product Description
Indoor Air Quality Monitor Logger Detector laser sensor TFT LCD screen Accurate Testing Data with PM2.5/PM1.0/PM10/TVOC/HCHO/AQI

 

 

Langder High Sensitivity PM2.5 Dust Meter Air Analyzer

Large LED Screen with Bright Backlight, Convenient To Use

An Ideal Tool To 24 Hours real Monitor PM2.5/PM1.0/PM10/TVOC/HCHO/AQI At Home 

Use For Office, Inside A Car Or During Interior Decoration and Outdoor Environmental Testing

It iS Pocket-sized,Very Convenient to Carry and Measure The Air Auality Around You. This Device Can Measure PM ,HCHO,TVOC. Besides, This Detector Can Be Programmed and Revise the Interface According to Your Preference. We Will Provide The Programming Instruction. 

 

Specifications: 

-Laser sensor
-2.8" TFT LCD screen display -320*240 pixels
-It can be used in office, indoor and fitment pollution detection
-24 hours real time monitoring
-Detection range: PM2.5(0-1000)
HCHO(0.001-1.999Mg/M³)
TVOC(0.001-9.999Mg/M³)
-Power supply:Built in Li-battery 2200mAh

 

 

Whats is Included:

1*PM2.5 Monitor

1*USB Cable

1*Use Manual

  

Note:

1.Items Must Be Placed on The Indoor Static More Than An Hour Then It Will Show The Actual Data. If Randomly Moved, The Data Will Be Inaccurate.

2.If You Can Ensure A Clean Environment, The Goods Can Be The Calibration Data, And Then Measure. If Items Are In Low Battery, The

Data May Be Inaccurate.

 

 

QA :

1 Q: Why do I need to calibrate?


A: Our products work in the form of outdoor formaldehyde-free air sampling as a benchmark, and then get indoor air formaldehyde content as a comparison, so the new machine products for a long time not used, the detection of environmental temperature changes need to change First calibrated and then tested, the value of this calibration for the subsequent detection of the accuracy of a great relevance. Calibration environment must avoid spices, perfumes, paint, cigarettes, air fresheners, alcohol and other chemical pollutants, so as not to damage the sensor.

 

2 Q: the test value has been 0, spray perfume will rise?


A: Please re-calibrate outdoors. Detection of spices, perfume, paint, cigarettes, air fresheners, alcohol and other chemical pollutants, so as not to damage the sensor.

 

3 Q: How much range of detection of formaldehyde concentration detector,how many square meters?
A:
1) The principle is less than 50m3 ,the room should be set 1 to 3 points;50 ~ 100m3 Set 3 to 5 points;More than100m3 at least 5 points. On a diagonal or plum blossom evenly distributed.
2) Sampling points should avoid the ventilation, from the wall distance greater than 0.5m.
3) The height of the sampling point: in principle, consistent with the human breathing.Relative height of 0.5m ~ 1.5m between.

 

4 Q: Why PM2.5 readings with the published value on the site is not the same?


A: Because the location and conditions of the test is difficult to reconcile with the weather station, the weather station in the city there are several sampling points, each sampling point measured data are also very different, the sampling point of the location is strictly required; height 3 to 30 meters, air circulation, can not be close to the chimney, furnace and other obvious sources of pollution. And there are no high-rise buildings, trees or other obstructions that can impede the flow of ambient air around the instrument.

 

5 Q: Why is the PM2.5 test value changing?


A: PM2.5 data are changing at all times, with the air, wind, humidity and other environmental factors change, in the room smoking, cooking fumes, car exhaust emissions, coal, chimney, furnace Such as pollution sources will change the PM2.5 value of this area, resulting in differences in the detection data.

 

6 Q: Why is the product sounding when working?


A: PM2.5 detection need to collect a lot of mobile air, in order to ensure accurate detection of the fan needs strong operation, so a little sound is normal.

 

7 Q: What is the standard for formaldehyde (HCHO)?


A: ≤ 0.10mg / m3 ("indoor air quality standards" GB / T18883-2002)

 

8 Q: What is the standard for total volatile organic compounds (TVOC)?


A: ≤ 0.6mg / m3 (GB / T 18883-2002 and GB 50325-2001 Class II civil construction)

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
Trade Assurance
China (Mainland)
Transaction Level:
Supplier Assessments:
3 Transactions 1,000+
The supplier’s transactions conducted via Alibaba.com in the past 6 months.
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $27,000
Learn More